Aquavar ABII Quick Start Guide
Installation Steps:
1. Install the Pump
• Plumb suction and discharge of pump into piping.
• Install a check valve on the suction side.
• Locate the pump as near liquid source as possible.
2. Install the Pressure Transducer
• Install the pressure transducer in the tank tee provided with the unit.
• Locate the transducer within 120” of the controller.
3. Mount the Controller
• Mount vertically in a well ventilated, shaded area with 8 inches of free air
space on every side and temperature between 34º F and 104º F.
4. Connect Input Power
• Connect the 1Ø power from a 20 amp 2-pole circuit breaker.
• Do not use GFCI protection with ABII as nuisance tripping will result.
5. Output Power Connections
• Connect the output power leads from the controller to the 3 motor leads
in the conduit box on the motor.
6. Set the motor Overload Switches (or dials, 3 and 5 HP)
• Complete systems have overloads pre-set at factory.
7. Set the Pressure - Factory pre-set is 50 PSI
• Push and Hold the Increase or Decrease Pressure Adjust Pushbutton
until the desired pressure setting is reached.
The maximum allowable pressure setting is 85 psi.
8. Set the Application Switches (or dials, 3 and 5 HP)
Minimum Speed of 10 Hz – the incoming pressure is within 20 PSI of the
desired pressure setting.
Minimum Speed of 30 Hz – the incoming pressure is 20 PSI or more below
the desired pressure, if pumping from a tank or if drawing a suction lift.
Ramp Speed – Slow - Low ow; Medium - Medium ow; Fast - High ow
QUICK START GUIDE
IMS-ABII-1
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - QUICK START GUIDE

Aquavar ABII Quick Start GuideInstallation Steps:1. Install the Pump• Plumb suction and discharge of pump into piping.• Install a check valve on the s

Seite 2 - Typical Installation

Aquavar ABII Controller Typical InstallationThis diagram shows a set-up for municipal water connection. This allows pump maintenance without main line

Seite 3 - Quick Start Up Guide

Aquavar ABII Quick Start Up GuideLABELS FOUND ON THE CONTROLLER ACCESS COVER: Fault CodesMotor Overload SettingWARNING: Disconnect Power And Wait For

Seite 4 - Aquavar ABII Wiring Diagram

Input230V1 PhaseGNDL1L2 (N)See Manual ForSwitch SettingsApplic.TypeOutputTo Motor1 2 3 4 1 2 3 4PressureTransducerInput (Wht)+5V (Red)Com. (Blk)T1T2T3

Kommentare zu diesen Handbüchern

Keine Kommentare