STEP 3 — Place impeller in chunk on drill table. Align
at mill cutting tool at center of imbalance point on
the impeller wall. If the unbalanced condition is quite
pronounced make the rst cut about 1/64" deep and
2" to the left and right of the center point.
FIGURE 6
This is done by moving the handle attached to drill
table back and forth. A continuous balance check
should be made during this operation. The impeller is
properly balanced when it remains stationary on the
balance ways on any point of its 360º periphery.